You are browsing the archive for 2011 March.

18th March – Solar Collectors and Cylinder

Mar 18 2011 in Uncategorized by bere:architects

Three new Vaillant AuroTHERM Exclusive solar thermal collectors

Last week, the solar thermal collectors were installed on the roof at Grove Road. These panels transform solar energy into heat energy using Glycol, a frost-protected solar fluid which circulates through the evacuated glass tubes of the collector and into a coil in the hot water cylinder. The new hot water cylinder, a Vaillant AuroSTOR [...]

Read more

7th March -Thermal Imaging

Mar 7 2011 in Uncategorized by bere:architects

Demonstration Thermography report 1 Testo 882-3

The front of the property showing very little insulation in the bay, particularly a very mysterious hot spot just above the window on the ground floor (we suspect this to be a heating pipe coming into close contact with the wall). It is easy to see the location of the radiator in the bay window [...]

Read more

7th March – Site Visit To Grove Rd

Mar 7 2011 in Uncategorized by bere:architects

Work has been progressing quickly at Grove Rd; recently the initial layer of insulation has been laid in the attic and the eaves of the property have been extended in order to accommodate the external wall insulation. A large part of the test with this particular retrofit project (and likewise the bere:architects’ Passfield Drive project) [...]

Read more